Changzhou Betterial Film Technology Co., Ltd.

Products

Electrical Insulation Base Film

    • Product Name: Electrical Insulation Base Film
    • Chemical Name (IUPAC): Poly(oxyethylene terephthalate)
    • CAS No.: 25038-59-9
    • Chemical Formula: C10H8O4
    • Form/Physical State: Film
    • Factroy Site: No. 666 Wujin East Avenue, Changzhou, Jiangsu, China
    • Price Inquiry: sales11@bouling-chem.com
    • Manufacturer: Changzhou Betterial Film Technology Co., Ltd.
    • CONTACT NOW
    VTB
    Specifications
    HS Code 238548
    Material Type Polyester (PET) or Polyimide
    Thickness Range 12 to 250 microns
    Dielectric Strength 100 to 350 kV/mm
    Thermal Class Class B (130°C) to Class H (180°C)
    Color Transparent or Milky White
    Surface Resistivity ≥ 1 x 10^15 Ω/sq
    Tensile Strength ≥ 150 MPa
    Elongation At Break ≥ 70%
    Moisture Absorption < 0.8%
    Flammability Self-extinguishing
    Chemical Resistance Resistant to most acids, alkalis, and solvents
    Shrinkage Rate < 2% at 150°C

    As an accredited Electrical Insulation Base Film factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing The Electrical Insulation Base Film is packaged in a sealed, moisture-proof carton containing 50 rolls, each securely wrapped for protection.
    Container Loading (20′ FCL) Container Loading (20′ FCL): Typically 10-12 metric tons of Electrical Insulation Base Film loaded, securely palletized, and moisture-protected, maximizing container space.
    Shipping **Shipping Description:** Electrical Insulation Base Film should be shipped in sealed, moisture-resistant packaging to prevent contamination and physical damage. Store and transport in clean, dry conditions, away from direct sunlight and sources of heat. Handle with care to avoid creasing or tearing. Follow regulations for chemical films where applicable.
    Storage Electrical Insulation Base Film should be stored in a clean, dry, and well-ventilated area, away from direct sunlight, heat sources, and moisture. It should be kept in its original packaging to prevent contamination and physical damage. Avoid contact with corrosive chemicals and ensure the storage temperature remains within recommended limits to preserve its insulating properties and overall quality.
    Shelf Life Shelf life of Electrical Insulation Base Film is typically 12 months if stored in a cool, dry place, away from sunlight.
    Application of Electrical Insulation Base Film

    Applications of Electrical Insulation Base Film in Industrial Manufacturing

    Our electrical insulation base film serves as a critical material foundation across multiple technical sectors that demand consistent dielectric strength, thermal stability, and mechanical integrity. As the material manufacturer, we support OEM and converter clients who require dependable insulation substrates in their downstream fabrication of quality-assured electrical and electronic components.

    1. Power Transformer and Motor Winding Insulation

    Major transformer and motor manufacturers rely on our insulation base film to provide primary winding barriers that maintain breakdown voltage and dimensional stability under prolonged electrical and thermal stress. The film consistently upholds dielectric integrity throughout production and operation, supporting winding configurations in high-output power distribution equipment to meet regulatory service requirements and help mitigate failure risks over extended lifecycles.

    Industry compliance standards

    • IEC 60216 (Electrical insulating materials—Thermal endurance properties)
    • IEC 60641 (Pressboard and presspaper for electrical purposes)
    • UL 1446 (Systems of insulating materials—General requirements)
    • RoHS Directive (Restriction of Hazardous Substances)

    Typical usage ratio

    • Film incorporated at 25–80 μm thickness, used in full wraps or layer separators at 12–25% by volume in winding assemblies, adjusted by voltage class and slot fill design

    Downstream process integration

    • Inserted after conductor coating, laminated or slit to spec width, then applied as turn/phase insulation manually or by automatic winding machines before vacuum drying or resin impregnation steps

    Final product types

    • Oil-immersed and dry-type transformers, high-voltage motor stators, wound rotor generators

    2. Flexible Printed Circuit Board (FPC) Substrate

    Electronics suppliers incorporate our material as the primary dielectric layer in FPC structures, taking advantage of its dimensional stability during repeated soldering cycles and its capacity for laser etching fine-line circuitry. The film provides key interlayer insulation and supports reliable adherence of copper laminates during high-volume, precision roll-to-roll fabrication for the consumer electronics and automotive electronics sectors.

    Industry compliance standards

    • IPC-4202 (Flexible base dielectric films)
    • IPC-2223 (Sectional design standards for flexible printed boards)
    • UL 94 VTM-0 (Flammability standard for flexible films)
    • REACH (Registration, Evaluation, Authorization and Restriction of Chemicals)

    Typical usage ratio

    • Used as 12–75 μm thick core layer, accounting for 50–70% of the total film content in FPC stack-ups; selected per bending radius and device layer count

    Downstream process integration

    • Feeds directly onto roll-to-roll lamination lines, followed by copper foil bonding, photoresist application, circuit patterning, and solder mask deposition in clean-room environments

    Final product types

    • Foldable smartphone circuits, automotive sensor flex circuits, wearable electronics ribbon cables

    3. Lithium-Ion Battery Cell Insulation

    Rechargeable battery manufacturers utilize our film as an internal cell separator and outer wrap to stabilize electrode spacing, minimize micro-short risks, and block electrolyte leakage in pouch, prismatic, and cylindrical lithium-ion cell formats. The material maintains microporosity and puncture resistance throughout winding, cell assembly, and electrolyte filling processes, aiding in yield rates and battery safety compliance.

    Industry compliance standards

    • UL 1642 (Lithium batteries—Safety standard)
    • IEC 62660-2 (Secondary lithium-ion cells—Safety testing for automotive applications)
    • GB/T 31485-2015 (Safety requirements for lithium-ion batteries in China)
    • UN 38.3 (Transport of Dangerous Goods—Lithium batteries)

    Typical usage ratio

    • Film thickness applied at 12–25 μm for separators, accounting for 8–15% of cell’s total internal mass, adjusted against energy density and safety margin requirements

    Downstream process integration

    • Fed into high-speed electrode winding or stacking equipment; thermally sealed as an outer wrap or slit and inserted between electrodes pre-impregnation with electrolyte

    Final product types

    • EV battery cells, portable device batteries, power tool rechargeable packs

    4. Electrical Tape and Wire Harness Sheathing

    Major tape converters and cable harness suppliers depend on our material as the mechanical and dielectric backing layer for electrical insulation tapes and complex wire harness assemblies in aerospace, automotive, and home appliance applications. The film’s consistent tensile strength and high adhesion performance meet the stringent requirements of downstream slit roll conversion and multi-layer wrapping under variable thermal and moisture environments.

    Industry compliance standards

    • IEC 60454 (Specifications for pressure-sensitive adhesive tapes for electrical purposes)
    • UL 510 (Standard for insulating tape)
    • ISO 6722 (Road vehicles—Conductors for insulated cables)
    • RoHS Directive (Restriction of Hazardous Substances)

    Typical usage ratio

    • Film thickness between 15–50 μm, constitutes 40–60% of tape structure by total thickness; content ratio tailored to insulation class, wrap tightness, and adhesion requirements

    Downstream process integration

    • Coated or laminated with pressure-sensitive adhesive, slit into narrow rolls or pre-formed sleeves, then applied by wrapping, spiraling, or heat shrinking over cable/conductor bundles

    Final product types

    • Electrical insulation tapes for automotive wiring, domestic cable harness tapes, aerospace wire bundles

    5. Capacitor Dielectric Layer Production

    Capacitor manufacturers use our film as the principal dielectric medium in the wound sections of film capacitors, benefiting from its low dielectric loss, high breakdown voltage, and freedom from pinholes. These properties are vital for reliable continuous roll vacuum metallization, slitting, and high-speed winding during the assembly of AC, DC, and pulse capacitors for industrial electronics, power compensation, and filtering.

    Industry compliance standards

    • IEC 60384-2 (Fixed capacitors for use in electronic equipment—Part 2: Sectional specification—Fixed metallized plastic film dielectric capacitors)
    • IEC 61071 (Capacitors for power electronics)
    • RoHS Directive (Restriction of Hazardous Substances)
    • REACH Regulation

    Typical usage ratio

    • Film thickness of 1–18 μm, incorporated at 80–95% of total dielectric stack by volume, adjusted for capacitance value and rated voltage class

    Downstream process integration

    • Metallized or left plain, slit into precision tapes, then wound into capacitor rolls under strictly controlled humidity, heat-annealed, and encapsulated in cans or end-sealed by welding

    Final product types

    • AC motor run capacitors, DC-link capacitors, power line filter capacitors, pulse film capacitors

    6. High-Voltage Cable Core Insulation

    Wire and cable producers require stable electrical base films for core insulation layers in high-voltage cables where precise wall thickness and dielectric uniformity are imperative. The film upholds mechanical elongation and insulation resistance even under continuous bending and pull-through during stranding, extrusion, and sheathing, ensuring certified cable performance in power distribution infrastructure projects.

    Industry compliance standards

    • IEC 60502 (Power cables with extruded insulation and their accessories for rated voltages from 1 kV up to 30 kV)
    • IEEE 1202 (Flame testing of cables)
    • UL 1072 (Medium-voltage power cables)
    • REACH Regulation

    Typical usage ratio

    • Film utilized as 40–120 μm layer in multi-layer composite insulation, accounting for 10–18% by total volume of insulated core, adjusted to voltage rating and environment exposure

    Downstream process integration

    • Inserted during the insulation forming stage, either as an extruded jacket reinforcement or spiral-wrapped around stranded conductor cores before subsequent layer lamination or jacketing

    Final product types

    • Medium and high-voltage power cables, wind turbine cable cores, underground and overhead transmission lines
    Free Quote

    Competitive Electrical Insulation Base Film prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618105193818 or mail to sales11@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618105193818

    Email: sales11@bouling-chem.com

    Inquiry

    Get Free Quote of Changzhou Betterial Film Technology Co., Ltd.

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Electrical Insulation Base Film: Building Reliable Barriers for a High-Performance World

    A Daily Foundation in Electrical Insulation

    Years spent on the factory floor and in technical meetings have shown me that dependable insulation makes all the difference to people building electronics, motors, and cables. Our electrical insulation base film, the M-180 model, reflects that hard-earned experience. Tough, stable, and built to handle wide temperature swings, it never sacrifices quality for speed or price. Engineers walk through our doors looking for a film that safeguards delicate copper windings, circuit layers, or core electronics, and we make sure they don’t leave disappointed.

    What Sets our Electrical Insulation Base Film Apart

    Every batch comes out of our reactors under careful watch. Constant polymerization yields a film with unmatched thickness control and surface stability. The M-180 hits a sweet spot: at 50 microns, it grants both flexibility and dielectric strength, supporting voltage ratings that satisfy rigorous international standards. Applications range from slot liners for industrial motors to insulation wraps in compact transformers. People count on performance, so each roll holds up against abrasion during winding and resists puncture in the field. Unlike lower-grade plastics from fast-moving lines, our film leaves no space for air voids or contamination.

    What Real Reliability Looks Like

    Through the years, people using lower-cost films often discover pinholes or inconsistent breakdown voltage. A batch might look similar until stress hits. A blown motor or a shorted PCB board means cost, reputation, and time lost. Our polymer chemistry forms a continuous, defect-free base, thanks to process control that keeps viscosity and residence time on target. Real customers have run our insulation through dry-type transformer factories, slotting and rolling layer after layer. They point out—less scrap, quicker throughput, and steadier final products. Overheating, shrinkage, or tear-down during winding can stop production in its tracks. We use controlled quench and orientation, reinforcing mechanical and thermal endurance. The M-180 film retains tensile strength beyond 170°C, keeping shape through cycles that warp or melt lesser films.

    Careful Material Selection: Why It Matters

    Polyethylene terephthalate (PET) earned its reputation for a reason. It withstands exposure to oil, most solvents, and humid conditions. In our electrical insulation base film, that means peace of mind. Whether facing daily power surges or sharp thermal rises, PET keeps the insulation stable. Various insulation films claim PET content. What makes a difference is polymer purity, resin filtration, and no shortcutting with recycled fractions. We keep a closed loop, eliminating foreign particulates that compromise infill. End-users tell us that after extended in-service aging, our film shows less yellowing and embrittlement, keeping insulating properties predictable.

    Thorough Testing Beyond Standard Requirements

    We take incoming resin and finished rolls through rigorous regimen—tracking dielectric strength, volume resistivity, elongation, puncture force, and electrical aging. ASTM D-150 and D-374 are basic benchmarks for us, not upper limits. Technicians probe every surface for corona resistance and test under humid, elevated temperatures. The M-180 film handles repeated flexing and rolling, keeping breakdown voltage well above 17 kV/mm even after hour-long heat exposures. Lower-spec products often underperform here. After years of field audits with transformer assemblers and wire harness makers, we’ve seen how everyday abrasion—or just one sharp tool—can ruin an entire batch of coiled wire. Our film absorbs shock without tearing.

    Applications That Demand More Than Just Insulation

    Few customers want a one-size-fits-all film. Our production runs cover continuous master rolls from 1,000 mm down to precision-slit spools, answering a need for various widths and windings. Distribution transformers, induction motors, electronic relay coils: each asks something specific. M-180 adapts with no need for secondary coating or lamination, which simplifies handling and adds value. Experienced operators recognize how a film that cuts clean, lays flat, and shows no surface contamination can increase output and lower rejected lots.

    The Difference in Performance: Real Shop Floor Experience

    Competitors sell insulation labeled as PET but vary on resin integrity and process methods. During actual plant visits, we’ve watched lines using off-brand film pause for clogging, stretching, or wrinkling. Customers stuck with these headaches lose time and risk supervisors’ patience on rework. Using our M-180 insulation film, lines run smoother and at rated speeds. The film lays evenly, and consistent surface energy keeps adhesives or laminates biting just right. On a production shift, that means fewer stoppages and easier training for new staff.

    What Ongoing Support Means

    We don’t stop at shipping finished rolls. Field teams and process engineers return customer calls, analyze line issues, and recommend storage or unwinding changes that protect the film’s handling. Lab staff offer advice if a winding or lamination machine throws a surprise problem. Hands-on troubleshooting, material compatibility checks, and even custom slit run tests push us to improve every batch. Plenty of trouble can lurk in hidden layers with insulation—oil additives, residual solvents, or incompatible adhesive films. Through technical support and continuous review, risks never go unaddressed.

    Environmental Standards, All the Way Back to the Resin

    Energy-efficient gear benefits both the user and our environment. Customers increasingly ask about the life cycle of insulation film. We document resin sourcing and demonstrate closed-process waste collection. Our plant aims for minimal off-gassing, proper solvent recovery, and integration with regional recycling programs. Each batch passes REACH and RoHS verifications, confirming that halogenated compounds and restricted metals never enter production. While the world debates green credentials, our material facts are clear—every step leaves a clean trace, and every audit is open for review.

    Why Dielectric Strength Matters in Equipment Life

    Over years at manufacturing plants building both film and finished transformers, failures traced back to insulation gaps or surface discharge taught us what works. The M-180 model posts high dielectric constants and no early breakdown under stress. High pulse voltages, switching surges, or thermal spikes all challenge insulation. Historical data ties longer equipment uptime to steady insulation behavior. Common substitutes, often filled with calcium carbonate or blended with secondary polymers, offer cost savings at the expense of current leakage or field breakdowns under damp conditions.

    Mechanical Strength for Today’s Compact Devices

    Electrification drives tighter design envelopes. Every millimeter inside an electric motor or relay station matters. Our M-180 insulation film brings high tear resistance, resisting slit-edge fraying. We’ve heard quality inspectors in cable plants highlight fewer edge curls and smoother layups, reducing both set-up waste and end-of-line failures. Semi-rigid character means film bends without memory but resists crushing, so finished coils assemble without tedious manual straightening. Compact assemblies benefit from a film that flexes enough to wrap sharp corners without splitting.

    Temperature Performance: Reliable Insulation Is a Margin of Safety

    Long before modern heating cycles and efficiency drives, insulation survived simple heat lamps and tape. Today, temperature spikes from automated lines, thermal cycling in high-voltage loads, and ambient rise from surrounding machines create harsh conditions. M-180 film survives these shifts with no visible shrinkage or mechanical weakening, maintaining dimensional tolerance. Statistical process control tracks every roll for shrink and elongation rates, and field reports confirm we’ve eliminated common failures like gap formation or slumping inside rotating machinery. Temperature-resilient insulation has moved from feature to basic requirement.

    Low Water Absorption, Safe Through Humidity and Floods

    Flood events, leaks, or ongoing high humidity environments can defeat insulation in matter of days. Water absorption raises risk of surface tracking, lowers dielectric properties, and accelerates aging. Field-tested M-180 base film keeps water absorption at levels far under PET average, due to resin selection and optimized heat treatment. Our test units stored in simulated monsoon conditions continue performing, resisting hydrolysis and chemical migration. Power plant operators and switchgear manufacturers credit this reliability for extended service intervals.

    Electrochemical Compatibility and Field Performance

    It’s not simply enough for an insulation film to sit between conductors; it must also interact safely with wire coatings, core fluids, and nearby gasket or potting materials. Our plant laboratory sessions ran M-180 through mixed-environment exposures—thermal oil baths, synthetic esters, cooling fluids, contact lubricants. No surface residue, no tackiness, and no adverse plasticizer migration. This compatibility secures insulation integrity across typical use-cases in switchyards, inverter rooms, and rotating machine shops. After years in service, the result stays the same—no blistering, no loss of structure.

    Outstanding Performance in High-Frequency and Pulse Applications

    Today’s power systems operate at higher frequencies to save energy and weight. Not every insulation film copes with these frequencies—corona discharge and partial tracking can erode less-stable plastics over time. Our M-180 base film remains stable under rapid pulse voltages, with electronic engineers confirming low partial discharge rates in stress testing. Transformer builders send us samples after a year in service, and we routinely see insulation that withstood every surge, ready for more years of operation.

    Surface Quality: Cutting, Printing, and Further Processing

    A key lesson from talking with downstream users—surface finish determines much more than appearance. An even, dust-free surface means easier cutting and laser marking. Barcode or logo printing rarely smears or flakes off. M-180 offers a stable corona-treated surface, ready for secondary process steps like lamination or printing, without clogged nozzles or pulled ink. Assembly teams value how tape or epoxy sticks solidly without peel-off failures, compared to films leaving oily residues or micro-wrinkles.

    Handling Safety and Consistency

    Operators handle insulation film all shift, so health and handling risks stay top of our agenda. We avoid unwanted plasticizers, keep all films phthalate-free, and monitor offgassing levels during production. Rolls ship with no sharp edges or loose particles, and jumbo slits run right on winding jigs with no snagging. End-users routinely report less maintenance, cleaner storerooms, and a safer workplace when using M-180 rolls in unrolling and stacking lines.

    Comparing the M-180 to Other Options

    With dozens of material samples in our quality control room each month, we see the full range of available insulation substrates on the market. Some offer only slightly lower cost, but at the price of reduced thickness precision or fluctuating resin batches. Others use filled or recycled content, which brings micro-bubbles or dust that accelerates aging. M-180 delivers a clear margin in absorbing voltage peaks, maintaining edge stability during high-speed winding, and reducing tiny defects that grow over months of vibration and heating. On real jobs, this difference cuts down end-of-line flaws, customer complaints, and costly rework.

    Repeatability, Batch to Batch

    Years of investment in local sourcing and upgrading plant processes pay off at every roll change. The M-180 film brings near-zero lot variation in dielectric breakdown, thickness, and surface resistivity. High-speed measurement and inline defect scanning catch anomalies early. Expert operators keep detailed logs and analyze trends, aiming for process drift elimination, not just detection. Users running automated coil or transformer winding lines benefit through stable run rates and fewer alarms.

    Working With Partners and Industry Feedback

    Staying close to electrical product manufacturers, we take feedback and field data seriously. Regular plant visits, sharing test results, and working through new application trials keep us sharp. Our R&D engineers collaborate on advanced multilayer structures or specialty flame-retardant versions, tested and tweaked based on customer pilot runs. The conversation continues after the shipment—new challenges drive upgrades to resin blends or minor process corrections, ensuring the next order just keeps getting better.

    Conclusion: Real Value Through Experience and Ongoing Commitment

    Manufacturing electrical insulation film goes well beyond melting resin and making flat sheets. It’s about listening to users, understanding machine stress, environmental demands, and maintaining a relentless focus on purity and consistency. We know that a single batch can make or break a production month for our customers—that sense of responsibility shapes every reactor change, test loop, and final roll loaded onto trucks. Customers return for M-180 film above all because it delivers a return on trust—equipment runs longer, costs drop, operators worry less. That’s the real story behind every meter of electrical insulation leaving our plant floor.

    Changzhou Betterial Film Technology Co., Ltd.

    Need Quality Chemicals You Can Trust?

    Get in touch with our team to discuss your chemical product requirements, request samples, or explore how we can support your business with tailored solutions.