    • Product Name: Ceramifiable Silicone Foam
    • Chemical Name (IUPAC): Polydimethylsiloxane
    • CAS No.: 68909-20-6
    • Chemical Formula: C2H6OSi
    • Form/Physical State: Foam
    • Factroy Site: No. 666 Wujin East Avenue, Changzhou, Jiangsu, China
    • Price Inquiry: sales11@bouling-chem.com
    • Manufacturer: Changzhou Betterial Film Technology Co., Ltd.
    • CONTACT NOW
    VTB
    Specifications
    HS Code 350626
    Material Type Ceramifiable Silicone Foam
    Color Typically off-white or grey
    Density 0.3 - 0.8 g/cm³
    Operating Temperature Range -60°C to 250°C
    Ceramification Temperature ≥800°C
    Thermal Conductivity 0.1 - 0.35 W/m·K
    Flammability Self-extinguishing
    Compression Set <15% (at 23°C, 25% deflection, 22 hours)
    Elongation At Break 80% - 150%
    Tensile Strength 0.3 - 1.0 MPa
    Water Absorption <1%
    Uv Resistance Excellent
    Electrical Insulation High
    Acoustic Insulation Moderate
    Ceramic Residue Forms rigid, insulating ceramic during fire exposure

    As an accredited Ceramifiable Silicone Foam factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing The packaging for Ceramifiable Silicone Foam consists of a 20 kg plastic pail, labeled with safety instructions, product name, and batch number.
    Container Loading (20′ FCL) Container Loading (20′ FCL) for Ceramifiable Silicone Foam: Typically loads about 9-11 tons, securely palletized to prevent contamination and damage.
    Shipping Ceramifiable Silicone Foam should be shipped in tightly sealed containers, protected from moisture and physical damage. Store and transport at ambient temperature, away from incompatible substances. Ensure labeling complies with local regulations. Use caution with heavy or large packaging and consult the Safety Data Sheet (SDS) for any specific transportation requirements or hazard classifications.
    Storage Ceramifiable Silicone Foam should be stored in a cool, dry, and well-ventilated area, away from direct sunlight and sources of ignition. Keep containers tightly sealed to prevent contamination and moisture ingress. Store separately from strong acids, bases, and oxidizing agents. Ensure proper labeling and secondary containment to avoid accidental spills or leaks. Follow manufacturer’s guidelines and local regulations for safe storage.
    Shelf Life Ceramifiable Silicone Foam typically has a shelf life of 6 to 12 months when stored in unopened containers under cool, dry conditions.
    Application of Ceramifiable Silicone Foam

    Applications of Ceramifiable Silicone Foam in Industrial Manufacturing

    As the manufacturer, we supply ceramifiable silicone foam for demanding industrial environments where advanced fire protection and thermal barrier integrity matter. This section details actual downstream manufacturing sectors. Each scenario outlines specific regulatory compliance, recommended material ratios, process integration points, and representative end products.

    1. Low-Voltage and High-Voltage Cable Fire Protection

    Ceramifiable silicone foam enables cable manufacturers to produce fire-resistant sheathing and bedding layers that maintain insulation function under extreme heat. On exposure to fire, the foam converts to a ceramic-like barrier, preserving circuit continuity and preventing toxic smoke release. Production engineers introduce the foam during cable compounding, with strict control of blend ratios to balance flexibility and protective ceramic yield.

    Industry compliance standards

    • IEC 60332-3-24 (Tests on electric and optical fibre cables under fire conditions)
    • EN 50200 (Fire resistance of unprotected small cables for emergency circuits)
    • UL 2196 (Tests for fire resistive cables)
    • GB/T 19216 (China national standard for fire-resistant cables)

    Typical usage ratio

    • 15–30% by weight in cable compound formulations. Adjust according to required ceramic residue, mechanical properties, and cable cross-section design.

    Downstream process integration

    • Added during internal mixing of base silicone polymers and additives, pre-extrusion. Compounded material extruded onto conductors as a sheath, bedding, or insulation layer before crosslinking or curing.

    Final product types

    • Fire-resistant power and control cables
    • Armoured signal cables for mass transport infrastructure
    • Emergency lighting circuit cables
    • Building safety cabling for fire alarm loops

    2. Tunnel and Metro Cable Tray Lining

    Critical tunnel infrastructure projects use ceramifiable silicone foam as a core layer in cable tray and duct lining. The material forms a coherent heat barrier during fire incidents, reducing collapse risk and supporting safe evacuation. Manufacturers formulate the foam into preformed sheets or mold it into complex tray geometries, ensuring dimensional stability and rapid installation on-site.

    Industry compliance standards

    • EN 1366-3 (Penetration seals for fire resistance)
    • DIN 4102-12 (Fire behaviour of building materials and structures — Cable trays and ducts)
    • NFPA 130 (Standard for Fixed Guideway Transit and Passenger Rail Systems)
    • BS 476-22 (Fire tests on building materials and structures, Part 22)

    Typical usage ratio

    • 20–35% by weight in molded or cast foam lining formulations. Ratio set based on required intumescent ceramic yield and heat exposure profile.

    Downstream process integration

    • Mixed into expanded silicone pre-polymer and cast or extruded into sheets or tray sections. Material cured on custom molds or pressed for direct lining application to cable tray slotted panels.

    Final product types

    • Fire-rated cable tray linings
    • Protective duct board assemblies
    • Integrated tunnel service duct barriers
    • Preformed fire-protection inserts for rail station cable troughs

    3. Automotive and Rail Vehicle Battery Compartment Seals

    Advanced vehicle OEMs specify ceramifiable silicone foam for use in battery enclosure gaskets and seals, especially for electric and hybrid models. During thermal runaway or external fire events, the foam chars and forms a rigid ceramic barrier, delaying heat transfer and inhibiting flame ingress. The foam is introduced during gasket compounding, offering a calibrated expansion profile to maintain specified seal tolerances.

    Industry compliance standards

    • ECE R100.03 (Electric vehicle battery safety)
    • UL 94 V-0 (Flammability rating for polymeric materials)
    • ISO 6722-1:2011 (Road vehicles – 60 V and 600 V single-core cables)
    • EN 45545-2 (Fire protection for rail vehicle materials)

    Typical usage ratio

    • 10–25% by weight in silicone-based foam elastomer blends. The ideal loading is tuned to end-use compression set, expansion, and ceramic formation criteria.

    Downstream process integration

    • Blended during closed-mill foam compounding, then injection or compression molded into custom gasket profiles. Final vulcanization and precision cutting performed before component delivery to assembly lines.

    Final product types

    • EV and hybrid battery enclosure gaskets
    • Onboard battery fire protection seals for metro rolling stock
    • Electric bus battery module spongy spacers
    • Thermal/fire barrier rings for battery access hatches

    4. Fire Door Core and Door Seals Manufacturing

    Manufacturers of commercial and emergency fire doors incorporate ceramifiable silicone foam into door cores and perimeter gasket systems. On exposure to high temperatures, the foam expands and transforms, creating a stable ceramic barrier that prevents fire and smoke passage. Foam integration methods focus on maintaining dimensional flatness and adhering to strict intumescent response timelines for compliance with door assembly fire rating tests.

    Industry compliance standards

    • EN 1634-1 (Fire resistance tests for door and shutter assemblies)
    • BS 476-22 (Methods for determination of fire resistance of elements of construction)
    • UL 10C (Positive Pressure Fire Tests of Door Assemblies)
    • ASTM E119 (Standard Test Methods for Fire Tests of Building Construction and Materials)

    Typical usage ratio

    • 12–28% by weight in foam core or intumescent gasket formulations. Blend ratio depends on panel thickness, target expansion, and composite material matrix.

    Downstream process integration

    • Added into core foam slurries or extruded into flexible seal strips. Shaped by continuous extrusion or batch pressing. Materials cured with adhesive backings or laminated inside steel or timber panels before door finishing operations.

    Final product types

    • Commercial fire door cores
    • Intumescent door perimeter sealing strips
    • Sliding fire curtain seals
    • Industrial smoke control door gaskets

    5. Electrical Equipment Safe Enclosure Panels

    OEMs integrating fire resilience into industrial electrical cabinets and distribution boards employ ceramifiable silicone foam as internal lining layers or cable feed-through barriers. Under fire conditions, the foam turns ceramic to protect vital components and delay enclosure breach. The material is incorporated as panels, tapes, or formed grommets tailored for critical junction boxes or MCCs (motor control centers).

    Industry compliance standards

    • IEC 61439-1/2 (Low-voltage switchgear and controlgear assemblies)
    • UL 508A (Industrial control panels)
    • NFPA 70 (National Electrical Code - requirements for fire-resistive enclosures)
    • GB 7251 (Low-voltage switchgear and controlgear assemblies – China)

    Typical usage ratio

    • 16–32% by weight in foam lining or fire-block insert compounds. The optimal range selected based on enclosure geometries and certification test results.

    Downstream process integration

    • Mixed into silicone prepolymer slurries for casting or hot pressing into sheets, die-cut for component panel fitting, or extruded into cable entry grommets. Components assembled during or post cabinet manufacture according to equipment build logic.

    Final product types

    • Fire-rated electrical junction boxes
    • Switchgear cabinet liner panels
    • Feed-through ceramic-forming grommets
    • Flame-resilient MCC component shields

    6. High-Rise Building Pipe Penetration Systems

    Specialists in firestop systems deploy ceramifiable silicone foam as the primary intumescent element in pipe and conduit penetration seals. When fire erupts, the foam expands and converts, maintaining compartmentation by blocking flame, gas, and smoke migration. Installers combine the foam in situ or as factory-molded collars and wraps, meeting local and international penetration integrity requirements.

    Industry compliance standards

    • UL 1479 (Fire Tests of Through-Penetration Firestops)
    • ASTM E814 (Standard Test Method for Fire Tests of Penetration Firestop Systems)
    • EN 1366-3 (Penetration seals for fire resistance)
    • IBC 2021/2024 (International Building Code - Firestop requirements)

    Typical usage ratio

    • 18–35% by weight in foam collars, wraps, and putties. The ratio aligns with tested gap fill, expansion, and ceramic formation benchmarks for each pipe diameter.

    Downstream process integration

    • Introduced during high-shear blending and extrusion or molding for collars and strip wraps. Pre-cured elements supplied to site or assembled in modular fire stop kits at the mechanical or MEP preassembly phase.

    Final product types

    • Intumescent pipe wraps for concrete floor and wall penetrations
    • Molded collar firestops for sheet metal, PEX, or uPVC pipes
    • Mechanical/HVAC conduit firestop seals
    • Fire-resistant putties for retrofit or service penetration management

    7. Data Center Raceway and Fiber Protection Systems

    Operators and fabricators of large-scale data centers implement ceramifiable silicone foam in the construction of raceway fire barriers and as protective sheets beneath fiber optic cable trays. The foam forms an effective ceramic shield under fire, preventing rapid rise of temperature inside containment and minimizing service interruption risks. Material dosing matches demanding test cycles required by hyperscale data and cloud infrastructure sectors.

    Industry compliance standards

    • NFPA 75 (Standard for the Fire Protection of Information Technology Equipment)
    • UL 2024 (Standard for Optical Fiber Cable Raceway)
    • ISO 11801 (Information technology – Cabling systems – Fire testing where applicable)

    Typical usage ratio

    • 12–22% by weight as core or interlayer material in tray or raceway fire barrier design. Adjust according to cable density and architectural fire compartment zoning.

    Downstream process integration

    • Foam introduced during casting or lamination of under-tray boards, co-extruded with raceway polymer skins, or die-cut for retrofit into pre-existing fiber tray arrays. Deployed during site fit-out or as an upgrade option for legacy containment systems.

    Final product types

    • Under-tray fiber optic raceway fire boards
    • Laminated raceway ceramic-forming panels
    • Retrofit fire barriers in cable tunnels
    • Data hall overhead tray thermal guards
    Free Quote

    Competitive Ceramifiable Silicone Foam prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618105193818 or mail to sales11@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618105193818

    Email: sales11@bouling-chem.com

    Inquiry

    Get Free Quote of Changzhou Betterial Film Technology Co., Ltd.

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Ceramifiable Silicone Foam: Raising the Bar for Fire-Resistant Materials

    The Real Challenge in Fire Protection

    At our production floor, demands from the construction, transportation, and cable industries have always run high for materials that will do more than just hold up under heat. Old-style silicone rubber foams give some resistance, but the moment temperatures blast above 250°C, those foams slump, vanish, or let flames through. For years, we watched insulation engineers wrestle with two conflicting needs: flexibility for installation, and the ability to stand up under crisis without falling apart or giving off choking fumes. Out of those challenges and direct customer feedback grew our ceramifiable silicone foam products—especially our signature high-performance grades—delivering the reliability missing from other fire-protection solutions.

    How This Foam Delivers in Fire Catastrophes

    Ceramifiable silicone foam answers a simple, tough question: what does your barrier become at 900°C? The answer is everything. Unlike classic foam that chars or melts into nothing, ceramifiable foam transforms into a rigid, ceramic-like shield when fire surges. Years ago, we saw clear failures. Cables would burn through, partition gaps would open, or public works inspectors would pull smoldering rubber from walls after a fire. We knew we could build a product to prevent those scenarios.

    Developed alongside experienced industrial scientists, our ceramifiable foams contain specific mineral fillers and catalysts. As intense heat strikes, these ingredients drive a chemical reaction: the old polymer backbone sheds water vapor and triggers ceramic ash formation. The result—foam that doesn’t only stay in place, but hardens into a strong shell, resisting collapse and maintaining low thermal conductivity throughout a prolonged blaze. This property separates ceramifiable foam from any regular fire-retardant silicone. Once installed around a cable tray or piping set, it stands between fire and assets, keeping its structure long after other foams disappear.

    Model Numbers and Trustworthy Specs

    Among our lineup, our CF-700 series stands at the core of current market demand. This line features low smoke emission, halogen-free chemistry, and a refined cell structure—features reflecting all the years our teams spent running small-batch experiments and tweaking compounding recipes. Standard densities range from 0.4 to 0.7 g/cm³, balancing softness for fitting around corners and density for real-world protection. Compression set performance stands out: time and fire both fail to collapse the foam easily. Once you press a slab of this material between fire collars or channel walls, it fills voids tightly, whether in vertical risers or cable trunkings, locking into place and ready to resist flame migration.

    We monitor and document expansion, mass loss, and ceramic strength in every production batch. Long-term field testing always mattered more than formal certificates. Building inspectors and fire engineers visiting our facilities often tell us: Certificates can look similar from supplier to supplier, but it’s those direct fire tunnel trials and on-site burn demonstrations that shape trust in a product. We stake our own reputation on our willingness to share real field test results, not just parchment from a standards lab.

    Hard Lessons from the Field

    Two decades manufacturing silicone materials have taught us that foam alone is never enough. Many buyers come to us after trying generic fire-retardant silicones. These might carry add-on powders or cheap flame-retardant additives just to hit minimal ratings—but their structure fails during high-intensity heat. In major tunnel projects in Europe and in subway retrofits, inspectors saw firsthand how basic foams crumbled or burned away, letting fire leap from one electrical system to another. Faulty or poorly-formulated firestop materials led to shutdowns, lawsuits, and heavy retrofit costs. As a manufacturer, we study these failures. Every feedback loop—every on-site installation, every real fire event report—filters into the next batch, into altered fillers, refined blowing agents, new mineral blends.

    Our ceramifiable silicone foam avoids these mistakes by using a closely-controlled compounding process. Fillers disperse consistently across every square centimeter. Cell size and distribution run tightly controlled, preventing hot gasses from tearing gaps during a fire surge. With the right mineral selection, the foamed product fuses into a semi-ceramic skeleton, maintaining a heat- and gas-blocking shell even after the silicone backbone has finished burning away.

    Distinct Advantages for Users and Installers

    Ceramifiable silicone foam helps the crew that must work fast and meet codes without breaking budgets. Unlike rigid boards, our foam presses into odd spaces and conforms tightly, eliminating air gaps. At the same time, it holds up to handling: tough enough to fight off cable drag and installer error. Unlike “swelling” intumescent pads that rely on chemical expansion, this foam forms its ceramic shield in place, meaning installers don’t need to worry about precise placement or expansion clearances. Material loss stays predictable and control over installation stays with your team, not with oversensitive, swelling materials.

    In every job—whether cable transits in a nuclear facility or the patchwork retrofits in an old train station—contractors favor the workability of our foam. Once cut, it holds its shape and size, and slices clean with standard site tools. Lay it around a pipe or stuff it inside a firestop sleeve; it expands slightly, then locks hard as soon as fire attacks. Handling, fitting, and reliability blend together—qualities our field staff and R&D teams hammer into every single batch that leaves the plant.

    Environmental Responsibility Without Compromise

    Insights from years spent managing plant emissions and working with eco-conscious partners pushed us to phase out halogens, avoid antimony trioxides, and eliminate other regulated flame retardants. Ceramifiable silicone foam, by its very formulation, gives off low toxic emission during both normal use and actual fire. Testing under both EN and UL standards consistently shows cleaner combustion profiles and lower mass loss rates compared to legacy foams. Our factory's downstream emissions audits stay clean, meeting both stringent European and Asian environmental codes without relying on greenwashing or paperwork trickery.

    We’ve seen project stakeholders demand life-cycle transparency. Investors, city planners, and transport operators want to know: how does this product behave at end of life? Our foams leave behind solid, stable ceramic residue, not sticky, hazardous threads or cancer-linked smoke. After fire, waste management crews can safely shovel up the ceramic crust for disposal, without facing secondary hazards.

    Side-by-Side with Other Materials

    Competitors bring lots of alternatives to the table: classic intumescent mastics, mineral wool slabs, and “hybrid” rubber blends. Each system has predictability problems: mineral wool cracks under vibration and needs trained hands, intumescents expand at poorly-controlled rates, and hybrid rubbers lose resilience before heat even becomes a problem. In our labs, side-by-side fire box testing always flags the same issues—a slab of ceramifiable silicone foam locks vapor and flame in place for far longer, while hybrid and intumescent systems leave holes or collapse before help can arrive.

    We found that only a material with genuine ceramification chemistry can solve the demanding scenarios inspectors face in underground tunnels, industrial switch rooms, and congested high-rise risers. The core benefits—holding mechanical shape, blocking smoke, and holding seal pressure—trace directly to our work on managing the ratio of mineral to polymer in every batch. Our teams keep strict controls over this process so installers and asset owners see consistent, trustworthy results no matter the season, humidity, or batch.

    Suitability Across Industries

    Our regular clients span broad sectors: infrastructure tunnels, power plants, marine shipbuilds, data centers, even sensitive pharmaceutical lines. Each application brings quirks and surprises. In marine work, salt spray attacks weak foams; ours resists. In powerplants, foams must slide past live gear without picking up static or off-gassing chemicals that corrode relay contacts. We gather customer feedback after each installation and feed those insights into our next product cycle. Those conversations matter more than any ad campaign. Compared to outdated “fire pillows” or fabric-reinforced foil wraps, ceramifiable silicone foam supports a lighter, cleaner, more reliable firestop presence in every job we see.

    Bulk cable tray fills in skyscraper projects present similar demands: the foam must squeeze tightly between angled bundles, avoid slumping, and never shrink out of place after years under load. Everybody in the building contracts business knows how much downtime and insurance risk climbs when shortcuts get taken with firestopping. We hear these stories first-hand when our own field techs visit sites and see the aftermath of minor fires or failed mockup tests. It keeps us honest in our design and compounding decisions.

    Continuous Development Born from Real Needs

    In manufacturing, sticking to what already works often leads to stagnation. Our research chemists and process engineers huddle every month, pouring over samples from jobsites and picking apart every failure. Ceramifiable silicone foam started out based on familiar siloxane chemistry, but we built it higher with a blend of new process controls and patience. Each time an engineer flagged smoke leakage or premature collapse after a major trial, our lab team came back with a tighter sieve curve for fillers, or a tweak in curing agent ratios. Unlike stamped commodities run off generic lines, every roll or slab that leaves our plant carries iterations from the real world.

    We believe progress only comes from hard confrontation with reality. Our willingness to engage with frontline installers—listening to complaints about stickiness in humid weather, or a batch that ran a shade too dense—forms the backbone of our product reliability. Technical support travels, not just issues PDF advice. Real improvement, not empty slogans, built the current generation of ceramifiable silicone foams we supply across several continents.

    A Reliable Ally in High-Risk Environments

    Upgrading fire protection isn’t about ticking-off compliance checklists. Factory owners, building managers, and underwater cable operators trust their assets to something real and tangible. A thin strip or pad of ceramifiable silicone foam, tucked away behind panels or embedded in risers, quietly does its job for years—unnoticed, until the worst happens. We saw the devastating aftermath of fires that jumped basic barriers, shutting down power grids or putting trains out of service. We designed this foam to stay rigid until the crisis has passed, holding gaps tight so first responders can work safely and assets remain intact.

    Tough feedback from job sites, earnest lab reports, and field observation set our standards. That’s reflected in how we mix, extrude, cure, and test every lot. We never lowball recipe ingredients or chase after short-term savings by substituting risky fillers. The same attention to performance that got us approvals for critical infrastructure jobs keeps us focused on long-term reliability, not fleeting marketplace trends.

    Modularity and Forward Compatibility

    Ceramifiable silicone foam fits within modular fire barrier systems. Its flexibility frees architects and engineers to specify custom wall penetrations without locking into rigid, one-use shapes. Contractors combine it with fire collars, split rings, gaskets, or wrap systems—meeting today’s needs but keeping space for tomorrow’s design changes. Clients appreciate that same batch supplied for a metro tunnel can also slot into a datacenter buildout, thanks to consistent expansion and fire test ratings.

    Unlike “novelty” firestop inventions in the market relying on exotic or unproven additives, our foam keeps its recipe transparent and compatible with standard cable trays, piping insulation, and vertical riser hardware. Disposals or upgrades don’t trigger surprises or restrictions—once its work is done, the rigid ceramic residue causes no headache for maintenance crews or environmental officers.

    Setting a Higher Bar for Safety, Backed by Experience

    Delivering fire-resistant materials is more than a transaction. Each shipment leaving the plant lays a portion of safety for whole buildings, tunnels, and communities. For us, the question isn’t just “does this pass a test,” but “how does this behave when the test turns real?” Every challenge from the field, every tricky retrofit and every major incident where our foam held the line, adds to our resolve to set new standards. Ceramifiable silicone foam isn’t a box-ticker; it earns its place beside fire doors, cable wraps, and wall penetrations by actual performance under fire, not just on spreadsheets.

    For those tired of guessing and gambling on commodity foams, this material offers a tangible step forward. Years of planning, patient compounding, and tough conversations with real installers and maintenance crews built what goes out with every order. We believe that seeing this foam perform under true crisis conditions is the only E-E-A-T principle that counts: experience, expertise, authentic performance—every batch, every year, across every job.

    Changzhou Betterial Film Technology Co., Ltd.

    Need Quality Chemicals You Can Trust?

    Get in touch with our team to discuss your chemical product requirements, request samples, or explore how we can support your business with tailored solutions.